SNV-12 Operations Manual
3-51
3.12.5.2
CPM Switch SW2 Settings
NOTE- Factory settings are marked *.
SW2- 1, 2, and 3 Voting Criteria; Signal Quality
These switches
determine the signal quality difference that must be exceeded before one SVM
is voted over another. If site "A" is presently voted, site "B" must maintain a better signal than
site "A" by the amount set by the dipswitches SW2-1, 2, 3 in order to be voted over site "A".
In addition, this threshold must be maintained for a period of time determined by CPM SW4
before the CPM will vote the new site. A 1dB setting is the typical threshold for voting
transitions. The 0dB setting should never be used; the voter may change sites based solely on
the random fluctuations always present in noise levels. More detail is provided in Section 5.6
Table 3-36
Voting Criteria
SW2-1
SW2-2
SW2-3
Signal Quality Difference
OFF
OFF
OFF
0 (Test Mode ONLY)
ON
OFF
OFF
1 dB *
OFF
ON
OFF
2 dB
ON
ON
OFF
3 dB
OFF
OFF
ON
4 dB
ON
OFF
ON
5 dB
OFF
ON
ON
6 dB
ON
ON
ON
7 dB
SW2-4 SVM Fault Reporting
This switch determines if a fault is reported (on the RS-232 Remote Control port, the system
fault output TB13-11, and the SVM fault output) when an SVM has been manually disabled at
its front panel. Although disabling a unit is not actually a fault condition, this gives a remote
console operator a way to know that someone set the SVM has been set to “DISABLE”,
thereby removing the site from service.
Table 3-37
SVM Fault Reporting
SW2-4
Setting
OFF
Front panel disable, not reported as Fault
ON
Front panel disable is reported as Fault
*
Содержание SNV-12
Страница 12: ...SNV 12 Operations Manual 12 This page intentionally left blank ...
Страница 22: ......
Страница 32: ...SNV 12 Operations Manual 3 4 SNV 12 Figure 3 1 Outline Dimensions ...
Страница 75: ...SNV 12 Operations Manual 3 47 ...
Страница 113: ...SNV 12 Operations Manual 3 85 Figure 3 12 SVM 1 Remote Receiver Audio Input ...
Страница 120: ...SNV 12 Operations Manual 3 92 Figure 3 19 SVM 2 for Type I Signaling ...
Страница 121: ...SNV 12 Operations Manual 3 93 Figure 3 20 SVM 2 for Type II Signaling ...
Страница 122: ...SNV 12 Operations Manual 3 94 Figure 3 21 SVM 2 for Type III Signaling ...
Страница 123: ...SNV 12 Operations Manual 3 95 Figure 3 22 SVM 2 for Type V Signaling ...
Страница 125: ...SNV 12 Operations Manual 3 97 Figure 3 24 CIM 2 for Type II Signaling ...
Страница 126: ...SNV 12 Operations Manual 3 98 Figure 3 25 CIM 2 for Type III Signaling ...
Страница 127: ...SNV 12 Operations Manual 3 99 Figure 3 26 CIM 2 for Type V Signaling ...
Страница 130: ......
Страница 142: ...SNV 12 Operations Manual 4 12 End of Section 4 ...
Страница 145: ...SNV 12 Operations Manual 5 3 Figure 5 1 RX Audio Delay ...
Страница 172: ...SNV 12 Operations Manual 5 30 This page intentionally left blank ...
Страница 196: ...SNV 12 Operations Manual 6 24 This page intentionally left blank ...
Страница 202: ......