SNV-12 Operations Manual
3-70
SW3-5 Voting Mode: FM mode or AM/HF mode
Turn this switch on to set the SVM to use an SNR measurement as the basis for voting, rather
than use the default noise-only voting mode. Use SNR voting mode for AM or HF systems.
Use noise-only voting for FM systems, and for other voting systems using signaling tones
(other than pilot tones) below 2200 Hz.
NOTE: If any SVM uses the AM/HF voting mode, all other SVMs must
also be set to AM/HF mode or improper voting will result.
Table 3-63
SW3-5 Voting Mode
SW3-5
Voting Mode Selection
OFF
FM mode *
ON
AM/HF mode
SW3-6 Simplex Repeat To Currently Voted Site
When in the Simplex Mode and the Repeat Mode, the SNV-12 normally will not send repeat
audio and keying commands to the voted site. This prevents the keying of a simplex transceiver
at the voted site, as keying would take the unit out of its RX mode, making it ineligible for
voting and setting up a feedback loop of voting, keying, un-voting, unkeying, voting, etc.
Some Simplex installations with separate transmitters and receivers or repeaters require that the
voted site receive repeat audio and keying signals. In these installations, Simplex Repeat When
Voted can be enabled on a site-by-site basis by turning SW3-6 On.
Table 3-64
Simplex Repeat When Voted
SW3-6
Repeat of Voted Site
OFF
Disabled *
ON
Enabled
Содержание SNV-12
Страница 12: ...SNV 12 Operations Manual 12 This page intentionally left blank ...
Страница 22: ......
Страница 32: ...SNV 12 Operations Manual 3 4 SNV 12 Figure 3 1 Outline Dimensions ...
Страница 75: ...SNV 12 Operations Manual 3 47 ...
Страница 113: ...SNV 12 Operations Manual 3 85 Figure 3 12 SVM 1 Remote Receiver Audio Input ...
Страница 120: ...SNV 12 Operations Manual 3 92 Figure 3 19 SVM 2 for Type I Signaling ...
Страница 121: ...SNV 12 Operations Manual 3 93 Figure 3 20 SVM 2 for Type II Signaling ...
Страница 122: ...SNV 12 Operations Manual 3 94 Figure 3 21 SVM 2 for Type III Signaling ...
Страница 123: ...SNV 12 Operations Manual 3 95 Figure 3 22 SVM 2 for Type V Signaling ...
Страница 125: ...SNV 12 Operations Manual 3 97 Figure 3 24 CIM 2 for Type II Signaling ...
Страница 126: ...SNV 12 Operations Manual 3 98 Figure 3 25 CIM 2 for Type III Signaling ...
Страница 127: ...SNV 12 Operations Manual 3 99 Figure 3 26 CIM 2 for Type V Signaling ...
Страница 130: ......
Страница 142: ...SNV 12 Operations Manual 4 12 End of Section 4 ...
Страница 145: ...SNV 12 Operations Manual 5 3 Figure 5 1 RX Audio Delay ...
Страница 172: ...SNV 12 Operations Manual 5 30 This page intentionally left blank ...
Страница 196: ...SNV 12 Operations Manual 6 24 This page intentionally left blank ...
Страница 202: ......