Quick Reference Table for  Manual Button Operation :

Action 

Required 

Step1 :  

LHS Button 

Step 2 : 

 RHS Button 

LHS 
LED 

RHS 

 LED 

Comment 

Power Adjust  1 x Push 

Each Push 
cycles 
through 
power 
levels 

Solid 
Red 

Green flashes 
indicate  level. 
High power (5 
flashes) to Low 
power (1 flash) 

Photocell 
Adjust 

2 x Push 

Each Push 
cycles 
through 
photocell 
levels 

Solid 
Green 

Green flashes 
indicate  setting. 
Low sensitivity to 
High sensitivity. 
Solid Red 
indicates 
Photocell 
disabled 

Status 
Indicator 
LEDS On / Off 

3 x Push 

Each Push 
cycles 
between 
On and Off 

Solid 
Amber 

On – Green 
Off - Red 

Factory Re-
set (Does not 
Re-set PIN) 

1 x Long 
Push  
(4 Seconds) 

Push and 
Hold until 
both LEDs 
flash Amber 

Flashing 
Red – 
After 4s 
Flashing 
Amber 

Solid Red – After 
4s Flashing 
Amber 

Reverts to 
Programming 
Mode unless a 
PIN is present. If 
a PIN is present 
reverts to 
original mode 
before re-set 

Disable 
Remote and 
Enter 
Operating 
Mode or 
Enable 
Remote and 
Enter 
Programming 
Mode 

1 x Long 
Push (4s) 
and 1 x short 
Push 

Push to 
cycle 
Disable / 
Enable 

Flashing 
Green 

Disable – Red 
Enable - Green 

Reverts to the 
Mode 
requested 
unless a PIN is 
present. If a PIN 
is present and 
you are in 
Operating 
Mode you 
cannot change 
to Programming 
Mode – unless 
you enter your 
PIN first 

www.ray

led

.com

Ray

LED

  Tel : +

33

(0)

 4 58 00 15 74

Содержание VARIO2 POE Series

Страница 1: ...d Operating Mode Page 12 VARIO Remote Controller VRC Page 14 PIN Function Guide Page 16 Manual Control Push Buttons Page 22 Disabling Manual Buttons Page 23 Power Up Functionality Re Set Options Page...

Страница 2: ...distance is 1500mm Max IR EHV Exposure Hazard Value 69 of Risk Group 2 Limit at 200mm from the illuminator Eye Safety White Light Variants Caution EN62471 Risk Group 2 Classification Possible hazardou...

Страница 3: ...g Contact volt free output Photocell Auxiliary Cable Premium Variants only Optional 24V DC power input red ve black ve External Input volt free or TTL orange TTL ve purple TTL GND External Output volt...

Страница 4: ...atible with your PoE equipment 24 9K is factory default Premium Variants For low voltage non PoE apply 24V DC to red and black cores of auxiliary cable Connect external inputs and external output wire...

Страница 5: ...ton Control Enabled Programming function will auto disable after 7 Days See Mode Power Up and Time Out Functionality Pg 23 Vario2 POE Complete Set Up and Installation STEP 1 Safety Information Pg 2 St...

Страница 6: ...r Ensure that the PSE is sufficiently rated to power the VARIO2 PoE device as follows Model Standard and Premium PoE Requirement VAR2 POE w2 1 i2 1 i2 1 C IEEE 802 3af HP PoE 12 95W VAR2 POE w4 1 i4 1...

Страница 7: ...Check with your supplier of PSE equipment For 24 9 K slide switch to the LEFT factory default as shown For 12 5 K slide switch to the RIGHT Power from 24V DC Premium Variants Only If using low voltag...

Страница 8: ...propriate volt free or TTL input Volt free input dry contact Non polarity sensitive short circuit light on TTL input Orange TTL ve Purple TTL ve GND 0V Light on 3V Light off Photocell following output...

Страница 9: ...20 x50 All ILS lenses will be clearly marked with the angle which they will produce when inserted into VARIO2 POE Please handle ILS lenses with care and do not touch optical film Only 1 ILS lens can b...

Страница 10: ...2 for detail on the LED status indicator feedback for these functions LHS RHS Programming Mode and Operating Mode Factory Default On initial power up the illuminator is in Programming Mode On powering...

Страница 11: ...NG GREEN Remote controller IR receiver problem Max VRC distance is 8m 26ft both modes RHS FLASHING AMBER Indicates unit is in programming mode Programming Mode Only RHS SOLID AMBER Indicates that a va...

Страница 12: ...tions provided with VRC when supplied Note Reset button will not remove a PIN if one is present Note Unless detailed as part of the functionality if an invalid or blocked command is attempted both LED...

Страница 13: ...he Vario Remote Control VRC There are five buttons characters on the remote that can be used for this purpose Please see PIN Function Guide P 10 for full details on how to use the PIN function Note Un...

Страница 14: ...red to complete the PIN entry There are four characters to be entered to successfully set up a PIN As you enter the characters the number of flashes will decrease until all characters are entered Note...

Страница 15: ...r into operating mode you will not be able to go back to programming mode without recycling the power Note If you forget your PIN and need to make adjustments to the illuminator you will need to perfo...

Страница 16: ...e or Enable Remote Controller and enter Programming Mode 6 Button Enable Disable In short the LHS button selects your mode category indicated by specific behaviours of the LHS LED and the RHS button s...

Страница 17: ...you can change the following configurations Illuminator Re set Enable Remote Controller and enter Programming Mode Disable Remote Controller and enter Operating Mode Manual Button Enable Disable Sequ...

Страница 18: ...level detailed in the following section you can lock in your settings in one of two ways 1 Press the LHS BUTTON to cycle through the modes until LHS LED extinguishes showing that you are at the end o...

Страница 19: ...or was in before selecting the manual controls The following modes are available Power Level Mode LHS LED Solid RED 20 Power Setting RHS LED 1 Flash GREEN 40 Power Setting RHS LED 2 Flashes GREEN 60 P...

Страница 20: ...LED Flashing GREEN and pressing a third time momentarily will turn the LHS LED Flashing AMBER Each of these colours indicates which setting mode you are in A further momentary press of LHS Button will...

Страница 21: ...Programming mode there are no restrictions Manual Control Buttons Enable Disable of LHS LED Flashing AMBER Enable Manual Button Control RHS LED Solid GREEN Disable Manual Button Control RHS LED Solid...

Страница 22: ...ognised and the indicator LEDs will not change RHS Button o The RHS button is functional with the Illuminator Configuration Mode In any other mode pushing this button will cause both indicator LEDS to...

Страница 23: ...ton press RESET Options There are Two Re set options for resetting your VARIO2 illuminator Settings Re set Pressing and holding the RESET BUTTON on the remote control or using the manual buttons to co...

Страница 24: ...e a straight 30 mins of safety time to change your mind where you can still use the buttons to re enable button control after this time has elapsed you can enter the PIN or do a full re set 2 If you d...

Страница 25: ...25 Standard Bracketry Supplied with the Product Model Dependant Not to scale dimensions rounded to nearest mm www rayled com RayLED Tel 33 0 4 58 00 15 74...

Страница 26: ...0ft 35m 115ft 50m 164ft 36m 118ft 25m 82ft 18m 59ft 14m 46ft 120 45m 148ft 25m 82ft 30m 98ft 24m 79ft 18m 59ft 14m 46ft 8m 26ft Consumption 49W max 47W max 25W max 15W max 25W max 8W max 9W max Input...

Страница 27: ...14m 46ft 8m 26ft Consumption 49W max 47W max 25W max 15W max 25W max 8W max 9W max Input POE or 24V DC POE or 24V DC POE or 24V DC Weight 1 75kg 3 85lbs 1 05Kg 2 31lbs 700g 1 54lbs Number of LED s 24...

Страница 28: ...itably rated for the VARIO2 POE unit see page 7 for required ratings Check polarity of illuminator connection red ve black ve Ensure power is 24V DC If longer cables used ensure sufficient voltage is...

Страница 29: ...FLASH RED but extinguish and revert to the standard SOLD GREEN when the correct voltage has been restored The fault indications are non latching Normal operating mode LHS SOLID GREEN Power Applied LHS...

Страница 30: ...amera is used and that the camera switches correctly into night mode Check camera and lens Is iris fully open at night and set correctly Ensure camera is fully operational and has correct night time s...

Страница 31: ...and serial number of illuminator Camera make and model Camera Lens make and model If the RayLED illuminator or remote control is still not delivering the required performance please contact us for fur...

Страница 32: ...Off Solid Amber On Green Off Red Factory Re set Does not Re set PIN 1 x Long Push 4 Seconds Push and Hold until both LEDs flash Amber Flashing Red After 4s Flashing Amber Solid Red After 4s Flashing...

Страница 33: ...rol can be used and 2 Operating Mode when most of the remote control functions are disabled see Remote Control Instructions for more details Manual Buttons are always available in programming mode or...

Страница 34: ...st Moon Max Timer Full Red Circle Timer Disable The unit will NOT accept any invalid characters and the countdown will not reduce If valid characters are entered in the wrong order when entering a PIN...

Страница 35: ...id Amber Flashing Red counts down the No of valid characters required Flashing Amber Stays in Programming Mode after PIN created or changed Enter existing PIN Prog Mode Press Status Button for 4 secon...

Страница 36: ...36 VA2 POE 16 1 0 www rayled com RAYLED VIRTUAVIA 2 RUE MARCEL BENOIT 38000 GRENOBLE FRANCE www RayLED com T l 33 4 58 00 15 74 Fax 33 9 55 70 03 53...

Отзывы: