The following modes are available:
Illuminator Reset Mode (LHS LED: Flashing RED)
RHS LED Solid RED
Keep RHS BUTTON depressed for 4 seconds. RHS LED stays solid RED and
then after 4 seconds both LEDs flash AMBER to show the illuminator has
been reset. This operation is equivalent to the factory reset button on the
remote control. It will not re-set a PIN if one is present.
Remote Controller Enable/ Disable(LHS LED: Flashing GREEN)
Enable Remote and enter Programming Mode: RHS LED Solid GREEN
Disable Remote and enter Operating Mode:
RHS LED Solid RED
Note : If there is a PIN present and the Illuminator is in Operating mode
you must enter your PIN to enable the remote and re-enter
Programming Mode or do a full re-set – See page 23– If no PIN is present
or you are in Programming mode there are no restrictions.
Manual Control Buttons Enable & Disable of (LHS LED: Flashing AMBER)
Enable Manual Button Control:
RHS LED Solid GREEN
Disable Manual Button Control:
RHS LED Solid RED
Note: If the illuminator is in Operating Mode and the buttons have been
disabled for at least 30 minutes, you cannot re-enable button control
without recycling power (if no PIN present) or entering your PIN or doing
a full re-set – See page 23.
Note – If no buttons are pressed within 2 minutes the illuminator times out
and returns to the previous mode it was in – either Programming Mode or
Operating Mode.
-
IMPORTANT:
When operating the manual buttons in either Illuminator
Settings Modes or Illuminator Configuration Modes (within
programming mode),
the Illuminator will default into Operating Mode
30 minutes after the last button press
(e.g. if you press any manual
button at 29 minutes – your 30 minute window will start over).