23
Power Up and Mode time-out Functionality :
After power is supplied to the unit :
If no PIN is present the Illuminator will go into Programming Mode for 7
Days and then will default to Operating Mode after this time has
elapsed.
- During this time if the remote is used to change settings the illuminator
will still default into Operating Mode after 7 Days from the power up
(unless the remote disable button is used to change the illuminator to
Operating Mode any sooner).
- However, if the manual push buttons are used at all during this time, the
illuminator will default into Operating Mode 30 minutes after the last button
press,
-
RESET Options :
There are Two Re-set options for resetting your VARIO2 illuminator
Settings Re-set :
Pressing and holding the RESET BUTTON on the remote control or using
the manual buttons to complete a RESET will restore the factory settings
to the illuminator. Note : If a PIN is present it will not be removed and the
illuminator will return to the mode you were previously in (Programming or
Operating) prior to the re-set command. Both indicator LEDs will flash
AMBER when completed.
Full Re-Set :
The other option to reset your illuminator is available by recycling the
power whilst holding down the two manual buttons. This is a FULL RESET
and will restore factory settings AND remove the PIN if one has been set.
Both Indicator LEDs will flash AMBER when completed.
www.ray
led
.com
Ray
LED
Tel : +
33
(0)
4 58 00 15 74