Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-A6000D~10000D
40
6.2 Emission external control mode set by power communication in ON mode
Figure 20 wiring diagram of Emission external control mode set by power communication in ON mode.
Operation methods
:
a) The rear panel air switch hits ON to supply power to the laser.
b) The front panel key switch is turned ON to put the laser into ON mode;
c) Open the upper computer software.
d) Click the red ON button to view the red light.
e) turn off the AD mode, open the external control mode; (this mode can be remembered when
the power is off)
f) click the main power ON button in the upper computer software to turn on the main power.
g) wait for the laser tricolor light green light to light up, the laser preparation work is completed.
h) Set the light output parameters.
I) External MOD signal output high level to turn on the laser.
j) Check the laser tricolor light is on red, the laser is outputting light