Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-A6000D~10000D
30
B10
Programming
mode execution
completed
Output signal
Output signal, indicating that the laser
programming mode is completed, the bit clears
when the A2 is invalid
B11
Abnormal Wave
Mode
Termination
Output signal
output signal indicating that the laser
programming mode is abnormally terminated
RESET (a4) cleared
B12
Synchronous
output
Output signal
Output signal, high effective, low invalid
B13
Warning output
Output signal
Output signal, indicating a warning to the laser
B14
Backup
B15
External power
supply
positive
The external 24 V input voltage, all table output
signal power supply, only these two feet access
24 V power output signal is effective
B16
Negative external
power
D1
~
D4
Current gate
channel
indication
Output signal
Output signal indicating the actual channel position of
the current gate.
0000-gate closed, channel 0001-1
selected, channel 0010-2 selected, channel
0011-3 selected (Open only to lasers with gate
pairs, other lasers this pin standby)
D5
Water cooler
warning
output
Output signal
Current water temperature warning
D6
Water cooler
alarm output Output signal
Current water temperature alarm
D7
Back up
D8
~
D11
Laser hardware
address
Output signal
Coding-Cable function ;0000-0 laser ,0001-1 laser;
D8 low, D11 high