Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-A6000D~10000D
47
c) Shorting pin 8 and pin 9 on XP2 to supply power to the main control board.
d) XP1-A1 is connected to 24V.
e) XP1-A5 is connected to 24V to turn on the red light; XP1-A5 is connected to 0V to turn off
the red light after checking the optics.
f) XP1-C1 is connected to 24V, and the main power is turned on (you can also press the LASER
button directly, or the upper computer software points the main power ON).
g) Wait for the laser tricolor light to turn on green, the laser preparation is completed.
h) XP1-(A8-14) select the pre-executed program number, XP1-A2 set to high to start the
execution of the program.
I) Check that the laser tricolor red light is on, and the laser is outputting light.
Figure 27 Timing diagram of control signal of programming mode.
7 RS232 and INTERNET Communication Command
7.1 Port Configuration
RS-232 configuration is as follows:
baud rate :9600, data bit :8, stop bit :1, no parity bit and no control flow.
Ethernet port is configured as follows: