POWER:
Control power indicator, when the white indicator light is on, it means the main control
system is on.
LASER:
The power button of the laser main power supply has a green light indicator function. After
the laser main control system is powered on and all INTERLOCKs are detected as normal, press this
button, the laser main power supply is powered on, and the button lights up after the main power supply is
powered on.
ALARM
:
INTERLOCK alarm indication, the ALARM indicator lights up during the power-on
self-check on the control panel. After the self-inspection is completed, all INTERLOCK interfaces are
normally closed, and the ALARM indicator is off. During the operation of the laser, any INTERLOCK
failure will cause the indicator to light.
STOP:
Emergency stop button, press it to turn off the laser immediately; turn clockwise to release
the button. Use the key to turn on the laser and power on the laser again to return to normal.
INDICATOR LIGHT:
After the main power supply of the laser is turned on, the green indicator
light is on when the laser is Ready; when the laser is emitting light, the red indicator light is on; when the
laser has a fault, the yellow indicator light is on, accompanied by an alarm sound.
4.2 Rear Panel
Figure 7 shows the rear panel.