Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-A6000D~10000D
21
Figure 10 Control signal line.
4.4.1 Safety XP2 Interface
24-pin safety interface, with remote control system power-on, remote main power power-on and
active and passive output of some lasers. The detailed interface definition is shown in Table 5.
Table 5 XP2 security interface definition
Pin
Number
Type
Description
1
MOD+
Output control, voltage input signal; laser ON
:
4
~
30V; Laser OFF
:
-3
~
2V.
Highest frequency 2kHz
2
MOD-
HARDWIRING
XP1
Security
interface
XP2
Analog
interface
XP4
Serial
interface
XP3
Communication
Interface XP5