55M4000BCE00 REV A
22
these figures as possible. Note, values for test loads greater than 90%SWL are shown
for reference only and should not be used for calibration purposes.
Test load
50%
60%
70%
80%
90%
100%
120%
Max Bits value
1765
2100
2430
2765
3100
3430
4095
If the reading is unacceptable then adjust the gain setting jumpers in the transducer
interface unit to achieve the closest possible setting, refer to the label inside the
interface unit for guidance. The standard gain setting number is 325, other options are
219, 253, 413, 579 and 630; a higher gain setting will result in a larger span setting
value.
Warning:
If the gain value is changed then redo the zero load calibration before
continuing with the span load calibration.
2)
Press
“
”
to edit the span load value.
3)
Edit the span value to read the value of the suspended load, then press
“
”
to
confirm.
4)
Press
Escape
to return to the sensor calibration menu.
Repeat step #13 for each load sensor in turn.