2.7 Step #7: “system options” setting
The system options menu allows various features to be turned on and off and may vary
depending on the version of software installed in the i4000 system.
These settings will
normally be pre-set before delivery and will not require changing.
Navigate through the calibration menu using
“
”
or
“
”
to highlight “system options”
and press
“
”
to enter.
Bypass Timeout.
Time allowed in seconds before to re-activate the motion cut after
pressed the Bypass key in normal mode.
Enable Radius Calcul.
This is to allow the calcul of the radius. All dimensions entered
must be conform.
Absolute Limiter.
This allow to enable the Absolute limiter.
Range Limiting.
This allow to enable the range limiting option. When the range limiting
is enable, the following 3 features will be displayed.
Save limit.
Optional feature, if enabled then setting this to ON will display a message on
start up indicating a limit is saved if a limit has previously been set.
Password Range.
When set to ON, Limits of the Range limiting feature is protected by a
password.
Password.
The Range Limiting feature will be protected by this password if set to a
value other than 0.
1-
To set-up a password for the Range Limiting option Press
“
”
to enter.
2-
The system will request a 5 digit password. The first digit will be highlighted, use
“
”
or
“
”
to select the first digit and press
“
”
to confirm and move on to the
second digit. Repeat this for all 5 digits, after confirming the 5
th
digit the system
will enter the calibration menu provided the password is correct. If the
password is not correct the system will return to the normal working screen.
3-
If a mistake is made while entering the password, press
“
”
to return to the
previous digit.