RaycoWylie i4000 Скачать руководство пользователя страница 12

55M4000BCE00  REV A 

12 

mode. If the wind speed goes over this approach gap an intermittent audible alarm 
will be activated and the yellow display LED will blink. 

 

App  Rotation(if  Rotation  sensor  fitted)  : 

This  variable  represents  an  approach 

warning gap before to reach the slew limit set by the operator in the normal mode. If 
the slew goes over this approach gap

 

an intermittent audible alarm will be activated 

and the yellow display LED will blink. 

 

Time of return

:  This is the time that you have to return into safe condition  before 

the motion cut output will be activated, when you reach a limit. 

 
2.6  Step #6:  “Dimensions” Data entry  

 
This menu contains crane dimensions that are necessary for the calculation of the load 
radius and height of the boom tip. 
Some or all of this information may be pre-loaded prior to delivery but all dimensions 
should be verified and edited as required before proceeding.  Units in use will be feet or 
meters depending on the setting made for ‘calib units’ in step #3.  To enter a negative 
value press on 

“+/-“

 to toggle  between positive and negative value. 

 

 

CL1 (full retract): 

length of the main boom when fully retracted. 

 

CL2 (Ext + Man)):  

length of the boom with all sections fully extended including any 

manual or power pinned extension if fitted. 

 

CL2MR (Ext + Man):  

length of the boom fully extended but with any manual or 

power pinned extension retracted.  Note: For full power booms without a manual 
section 

CL2

 and 

CL2MR

 are the same value. 

 

CL8 (p2cb) 

– vertical distance between the boom foot pin and the boom centerline 

with the boom horizontal.  Instead of using the boom centerline as a reference, It is 
common to use the boom foot pin, in this case CL8 = 0 but ensure that CL10 and CL11 
use the same reference. 

 

CL10 - 

vertical distance between the lower boom tip sheave pin (hook suspension 

sheave) and the boom centerline (or boom foot pin, see CL8) with the boom 
horizontal. 

 

CL11 - 

vertical distance between the upper boom tip sheave pin and the boom 

centerline (or boom foot pin, see CL8) with the boom horizontal. 

 

CR1 (Sheave Rad.) - 

lower boom tip sheave pitch radius (hook suspension sheave).

 

 

CF (slew offset)

 – horizontal distance between the boom foot pin and the centerline 

of rotation of the machine.  If the boom foot pin is behind the centerline of rotation 
then the distance is negative, otherwise it is positive. 

 

CH1 (height offset) 

– 

vertical distance between the boom foot pin and the ground. 

 

Nb Jib 

– Number of jib available to calibrate

, if this value is greater than 0, we will have 

to enter dimension shown in “Fly jib geometry” for each jib.  
 

 

Содержание i4000

Страница 1: ...tem Drury Lane 1020 9 th Avenue SW 2440 Ave Dalton St Leonards on Sea Suite 124 Ste Foy East Sussex Bessemer AL 35022 Qu bec G1P 3X1 England U S A Canada TN38 9BA Tel 44 0 1424 421235 Tel 1 205 481 20...

Страница 2: ...55M4000BCE00 REV A 2...

Страница 3: ...on and or modification of the equipment are strictly forbidden without written approval from RaycoWylie Systems The i4000 RaycoWylie Systems Multi Purpose Indicator MPI is to be regarded only as an ai...

Страница 4: ...manual and the crane manufacturer operator s manual He must also be aware of all the federal state and local safety standard and regulations applicable to his job Correct functioning of the system dep...

Страница 5: ...sions Data entry 12 2 7 Step 7 system options setting 15 2 8 Step 8 Internal Relay Set Up 16 3 CALIBRATION 17 3 1 Step 9 Zero sensor Side of boom angle angle sensor calibration 17 3 2 Step 10 Zero sen...

Страница 6: ...rformed by a qualified technician Furthermore calibration of the i4000 system must be performed by a RaycoWylie trained technician The RaycoWylie technician will perform a complete and structured veri...

Страница 7: ...ll left through the tabs of the main menu or in Edit mode to return to the previous digit of a configurable value Right Key Press this key to scroll right through the tabs of the main menu or in Edit...

Страница 8: ...RANGE LIMITING TAB TOOLS TAB 2 1 Step 1 Accessing the calibration menu 1 Select the tool tab using the left or right keys 2 Scroll to highlight Calibration Mode using or 3 Press to enter this menu 4...

Страница 9: ...oll to select the sensor option to edit 4 Press to highlight the value to edit Scroll up or down to change to value then Press to confirm 5 Any change made is permanently registered after confirmation...

Страница 10: ...ey at any time to exit the menu when done Rope Limit Main This is the maximum tension that the cable is rated for per fall or part of line rope SWL for the main rope Rope Limit Aux This is the maximum...

Страница 11: ...ill be activated and the yellow display LED will blink App Length This variable represents an approach warning gap before to reach the boom length limit set by the operator in the normal mode If the b...

Страница 12: ...m with all sections fully extended including any manual or power pinned extension if fitted CL2MR Ext Man length of the boom fully extended but with any manual or power pinned extension retracted Note...

Страница 13: ...the centreline of slew is generally in front of the boom pivot pin in which case cf is negative If any other dimension falls the opposite side of it s datum line shown in the diagrams then it s sign...

Страница 14: ...55M4000BCE00 REV A 14 Rooster sheave geometry Fly jib geometry...

Страница 15: ...is enable the following 3 features will be displayed Save limit Optional feature if enabled then setting this to ON will display a message on start up indicating a limit is saved if a limit has previ...

Страница 16: ...16 2 8 Step 8 Internal Relay Set Up This item allows the selection of which option the internal relay will be activated There is three options which are available Absolute limiter Overload and Range...

Страница 17: ...switch setting for each angle sensor interface Angle Sensor Side of Boom 1 Use or to choose Sensor Calibration and press 2 Use or to choose the Select Sensor and press the Use or again to choose the...

Страница 18: ...the sensor to increase the value 3 Press to edit the angle value using or 4 Press again to confirm the zero 5 Press Escape to return to the main calibration menu The boom angle need not be zero but it...

Страница 19: ...libration 1 Use or to choose span and press 2 Fully extend all the boom sections up to and including the section that the length sensor cable is attached to for single reel installations this is all b...

Страница 20: ...ust be done with two accurately known test loads a small load and a large load The large calibration load should provide between 50 90 line pull on the hoist line while using as many parts of line as...

Страница 21: ...ue of the suspended test load then press to confirm the value Note the indicated value will return to its earlier state temporarily the new zero value will be stored after the next step 4 Press Escape...

Страница 22: ...closest possible setting refer to the label inside the interface unit for guidance The standard gain setting number is 325 other options are 219 253 413 579 and 630 a higher gain setting will result i...

Страница 23: ...te encoder is fitted as the slew sensor If a relative encoder as 33M0118 is installed and selected you don t need to do the zero To set the zero datum Rotate the machine to the zero datum point normal...

Страница 24: ...f bits for single 360 rotation of the crane only if you have selected a multi turn encoder as 33S0047 otherwise the value stays at zero 4 Press Escape to return to the main calibration menu Inverse Ro...

Страница 25: ...ss to enter The display will show the current boom length and a target boom length for calibration With the hook block suspended telescope the boom out to the target length specified on the display th...

Страница 26: ...or to adjust the Corr x x value until the displayed radius equals the measured radius note that the indicated radius can only be increased not decreased Press to accept the change the system will save...

Страница 27: ...om angle for calibration normally 60 Adjust the boom angle to the target angle when the boom is at the correct angle for calibration the display will change to show Carefully lift the test load until...

Страница 28: ...fer and press to enter 2 Select Calibration to USB and press a copy of the calibration information will be created in a file called cranename_000000 cal located in the root folder of the USB memory st...

Страница 29: ...tor USB of the i4000 display unit using a Deutsch to USB converter lead RaycoWylie part no 33V0338 before proceeding Ensure the file required to be restored is saved in the root folder of the USB stic...

Страница 30: ...ing this option if in doubt don t Init all memory Select this option to re initialize the system memory a warning screen will be displayed to ask for confirmation if confirmed all calibration data wil...

Страница 31: ...t hand side of this screen represent a count of the number of individual faults detected for each component and can be useful in tracing system faults Navigate through the calibration menu using or to...

Отзывы: