![background image](http://html2.mh-extra.com/html/raven/scs-4600/scs-4600_operators-manual_3858492062.webp)
57
APPENDIX 7
VERIFICATION OF SPREADER CONSTANT
To verify and refine the Spreader Constant, perform the following procedure (after completing INITIAL
CONSOLE PROGRAMMING):
1)
Weigh loaded truck and note weight.
2)
Enter the Product Density in lbs/cu.ft. [grams/liter] into key labelled .
3)
Enter a "0" into the key labelled
.
4)
With the rate switch in the MAN position, unload a portion of the load by positioning the boom switch
to ON.
5)
Determine the actual weight unloaded by re-weighing the truck.
6)
Compare to the TOTAL VOLUME displayed by the Console.
7)
Perform the following calculation to correct the Spreader Constant if desired:
Corrected Spreader Constant =
old Spreader Constant x TOTAL VOLUME
actual weight unloaded
EXAMPLE:
old Spreader Constant
=
228 [797]
TOTAL VOLUME amount
=
2000 lbs [4400 kg]
actual weight unloaded
=
1950 lbs [4290 kg]
English (US):
Corrected Spreader Constant (1 lb) =
228 x 2000
=
234
1950
Metric (SI):
Corrected Spreader Constant (1 kg) =
[797] x [4400] =
[817]
[4290]
This is the new Spreader Constant. Repeat this procedure until the weight of the metered material
equals the TOTAL VOLUME value.
Содержание SCS 4600
Страница 1: ...Operators Manual SCS 4600 SCS 4600 SCS 4600 SCS 4600 SCS 4600...
Страница 10: ...5 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 11: ...6 SECTION 1 LIQUID AND GRANULAR APPLICATIONS LIQUID AND GRANULAR APPLICATIONS...
Страница 15: ...10 FIGURE 3 BATTERY CONNECTIONS LIQUID AND GRANULAR APPLICATIONS...
Страница 34: ...29 FIGURE 6...
Страница 37: ...32 GRANULAR APPLICATIONS SECTION 2 GRANULAR APPLICATIONS...
Страница 38: ...33 FIGURE 7...
Страница 44: ...39 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 45: ...40 CAN APPLICATIONS SECTION 3 CONTROLLER AREA NETWORK CAN...
Страница 47: ...42 CAN APPLICATIONS FIGURE 13 FIGURE 14...
Страница 48: ...43 FIGURE 15...
Страница 49: ...44 CAN APPLICATIONS FIGURE 17 FIGURE 16...