SUBMENU: PRODUCT (PAGE 2)
DISPLAY
DESCRIPTION
SPREADER CONSTANT
Not applicable in liquid mode. A value of zero should be used when applying
liquid. See Granular Applications Section for calculating when in granular
mode. Spreader constant can be entered during initial programming or
through the DATA MENU.
PUMP CAL / FAN CAL
Set the number of pulses per revolution of the pump/fan for Pump/Fan RPM
readout.
DUAL SENSOR ALARM %
For Liquid Chemical Injection applications, sets tolerance between flow
switch monitor and flow readings before "FLOW SW" alarm is enacted. For
Gran 3 applications, sets tolerance between dual encoder readings before
"DUAL FLOW" alarm is enacted. (Boom Select feature must be set up for
only booms being used.) Out of tolerance condition must be met for 5
seconds before alarm occurs.
VACUUM ALARM or
When controlling chemical injection, the vacuum alarm can be enabled or
BIN LEVEL ALARM
disabled. Disable when not controlling injection. For granular applications,
bin level sensor can be enabled or disabled. Disable when bin level sensor
is not present.
FLOW SWITCH ALARM
When controlling chemical injection, the flow switch alarm can be enabled or
disabled. Disable when not controlling injection.
PRESSURE
Displays PSI [KPA] of pressure transducers.
BOOM PRESSURE
Used to calibrate Pressure Transducer #1. With pump turned off and 0 PSI
[KPA] on the line, enter a Pressure 1 of 0.
SPARGE PRESSURE
Used to calibrate Pressure Transducer #2. With pump turned off and 0 PSI
[KPA] on the line, enter a Pressure 2 of 0.
HIGH BOOM PRESSURE
If Boom PSI transducer (Pressure 1) in installed, sets the maximum
pressure allowable for the boom. If maximum pressure is exceeded, control
will be overridden and the control valve will be closed until a safe operating
pressure is reached. Function is disabled if a value of "0" is entered.
PWM OUTPUT
Status of PWM Output (if applicable) can be monitored. Output will range
from 0-255. A value of 0 indicates an OFF state. A value of 255 indicates
the PWM valve is wide open.
SUBMENU: CONSOLE
CONTRAST
Press to adjust LCD contrast. Press and hold
to lighten or
to darken. Press
again when complete.
AUDIBLE ALARM
Turn audible alarm ON or OFF.
Содержание SCS 4600
Страница 1: ...Operators Manual SCS 4600 SCS 4600 SCS 4600 SCS 4600 SCS 4600...
Страница 10: ...5 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 11: ...6 SECTION 1 LIQUID AND GRANULAR APPLICATIONS LIQUID AND GRANULAR APPLICATIONS...
Страница 15: ...10 FIGURE 3 BATTERY CONNECTIONS LIQUID AND GRANULAR APPLICATIONS...
Страница 34: ...29 FIGURE 6...
Страница 37: ...32 GRANULAR APPLICATIONS SECTION 2 GRANULAR APPLICATIONS...
Страница 38: ...33 FIGURE 7...
Страница 44: ...39 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 45: ...40 CAN APPLICATIONS SECTION 3 CONTROLLER AREA NETWORK CAN...
Страница 47: ...42 CAN APPLICATIONS FIGURE 13 FIGURE 14...
Страница 48: ...43 FIGURE 15...
Страница 49: ...44 CAN APPLICATIONS FIGURE 17 FIGURE 16...