![background image](http://html.mh-extra.com/html/raven/precision-autoboom-g1/precision-autoboom-g1_calibration-and-operators-manual_788825013.webp)
Manual # 016-0130-019
1 1
Problem 3:
Autoboom activates but the boom isn’t controlled or the boom
won’t come up.
Solutions:
1. The driver on the proportional valve is wet. Look at the ‘clear’ window and
identify if there is moisture inside.
2. Look at the green LED’s inside the controller and identify if there is any infor-
mation on the driver.
Problem 4:
Cannot set the static pressure. The booms keep falling when the
down dials are on 0.
Solution:
Reset the ‘Max’ pressure on the Down Speed dials. The booms have to
be creeping up on the ‘Max’ setting, usually around 200 psi higher than the static
pressure.