Troubleshooting: Diagnostic Trouble Code (DTC) List
61
TROUBLESHOOTING
8. Use a small jumper wire (e.g. paper clip) to short the ground and signal sockets with a “short-no short” motion.
Each time the short is made, the total volume value should change by increments of one or more.
9. If the total volume does not increase, disconnect this section of flow meter extension cable and repeat this test
at the next connector closest to Product Controller II ECU. Replace defective cable as required.
10. If all cables test good, replace the flow meter.
11. After testing is complete, re-enter correct meter cal value and units.
DIAGNOSTIC TROUBLE CODE (DTC) LIST
The following trouble codes may be displayed by the Hawkeye
®
nozzle control system and should help the
operator to identify and correct issues with system during field operations:.
Code ID
Description
Recommended Actions
10
.13
UT display is not on-line
1. If this error occurs frequently, check the
ISOBUS connections and review the UT
display troubleshooting procedures.
2. Connect the Raven Service Tool to the
ISOBUS and verify communication.
158
.1
Logic SW power error
1. Verify logic voltage is at or above 4.8v to
Product Controller II ECU.
168
.1
Battery voltage error
1. Verify HC voltage to Product Controller II ECU
is above 9v.
630
.13
System calibration required
1. Complete the calibration wizard to configure
all required Hawkeye
®
system settings. Refer
to Chapter 3, System Calibration for
additional assistance with the calibration
wizard.
.31
Nozzle Calibration Error
1. Complete the calibration wizard to configure
all required Hawkeye
®
system settings. Refer
to Chapter 3, System Calibration for
additional assistance with the calibration
wizard.
2. Cycle system power.
3. Reset defaults.
Содержание ISO Product Controller II
Страница 1: ...ISO Product Controller II and Hawkeye Operation Manual P N 016 0171 584 H 01 19 E32470 Copyright 2019...
Страница 10: ...CHAPTER 1 viii ISO Product Controller II and Hawkeye Operation Manual...
Страница 16: ...CHAPTER 1 6 ISO Product Controller II and Hawkeye Operation Manual...
Страница 22: ...CHAPTER 2 12 ISO Product Controller II and Hawkeye Operation Manual...
Страница 50: ...CHAPTER 4 40 ISO Product Controller II and Hawkeye Operation Manual...
Страница 92: ...APPENDIX A 82 ISO Product Controller II and Hawkeye Operation Manual...
Страница 95: ...P N 016 0171 584 H 85 FIGURE 3 Generic Cabling for Self Propelled Sprayer...
Страница 97: ...P N 016 0171 584 H 87 FIGURE 5 Generic Cabling for Pull Type Sprayer with Existing Raven CAN...
Страница 99: ...P N 016 0171 584 H 89 FIGURE 7 20 Spacing Generic Cabling...
Страница 111: ...P N 016 0171 584 H 101...
Страница 112: ...APPENDIX D 102 ISO Product Controller II and Hawkeye Operation Manual...
Страница 116: ...APPENDIX E 106 ISO Product Controller II and Hawkeye Operation Manual...
Страница 120: ...APPENDIX F 110 ISO Product Controller II and Hawkeye Operation Manual...
Страница 122: ...APPENDIX G 112 ISO Product Controller II and Hawkeye Operation Manual FIGURE 1 Hawkeye Screen Flow Tools Menu Softkey...
Страница 125: ...P N 016 0171 584 H 115 FIGURE 4 Hawkeye Screen Flow Tally Registers and Diagnostics Menu Softkeys...
Страница 127: ...P N 016 0171 584 H 117 FIGURE 6 Hawkeye Injection Screen Flow Product Setup Alarms and System Information...
Страница 128: ...APPENDIX G 118 ISO Product Controller II and Hawkeye Operation Manual...
Страница 134: ...APPENDIX H 124 ISO Product Controller II and Hawkeye Operation Manual...