System Calibration: Initial Start Up and Calibration Wizard
15
SYSTEM CALIBRATION
6. Select the Tip Size field and use the available options to select the orifice size of the tips currently installed on
the nozzle bodies.
•
NCV is the tip connected to the Hawkeye
®
valve. The Bypass Tip is for secondary tips at each
nozzle.
•
If no tips are installed and liquid fertilizer is being applied, select NA as the tip size.
7. Select the Next button to proceed to the Nozzle Indexing prompt.
AUTOMATIC NOZZLE INDEXING
The automatic nozzle indexing process allows the Hawkeye
®
system to automatically configure the location of
each nozzle control valve on the left and right boom circuits and may detect issues with system connection or
nozzle setup.
1. When prompted, select the Next button to begin the auto-indexing process.
2. Hawkeye
®
will begin indexing nozzle control valves from the center of the implement boom and move out to
the end of the left boom. The indexing process automatically repeats for the right boom circuit, starting from
the center and working towards the end of the boom. If an error is detected on either the left or right boom
circuits, the Hawkeye
®
Product Controller II ECU will halt the indexing process and prompt the machine
operator to correct the error before continuing with the calibration wizard. If an error occurs, troubleshoot the
issue and press retry.
FENCE ROW SETUP
Fence row setup is only available if Sprayer was selected as the applicator type. If Applicator was selected, fence
row setup is skipped.
1. The Fence Row Setup prompt will display once the automatic indexing process completes.
2. Enable the fence row option if fence row valves are connected to the system. Select the Enable On Screen
Buttons box to control fence row valves through the on-screen interface. If using secondary input switches to
the boom sense for fence rows, enter the appropriate section input for the left and right fence rows.
3. Select the Next button to continue to the Section Setup prompt.
SECTION AND SWITCH SETUP
1. Select the Number of Sections field and enter the number of section on/off valves available for Hawkeye
®
section control.
NOTE:
Liquid fertilizer applicators running
Hawkeye
®
must have a single master valve instead of multiple
section valves. In this case, enter the number of toolbar sections. For example, a toolbar that folds
twice on each side would have five sections (L outer, L inner, Center, R inner, R outer).
2. Select the Next button to display the Section Width Setup prompt.
3. Select the Section Width fields and enter the width of each section across the implement. In Applicator mode,
enter the number of Hawkeye
®
NCV’s in each toolbar section.
a. Section 1 is always the farthest left section on the implement and the highest section number is always the
farthest right section.
b. Measure the width of the boom (or count the number of nozzles and multiply by the nozzle spacing)
controlled by each section and enter the section measurements to ensure that the system accurately
records section coverage during field applications.
c. For liquid fertilizer applicators in Applicator mode, the Hawkeye
®
NCV’s at each end of the toolbar are
each treated as half a row. For example, an outer section consisting of four nozzle control valves with 30”
spacing would have a section width of 30” + 30” + 30” + 15” = 105”.
4. Touch Next to display the Boom Offset page.
Содержание ISO Product Controller II
Страница 1: ...ISO Product Controller II and Hawkeye Operation Manual P N 016 0171 584 H 01 19 E32470 Copyright 2019...
Страница 10: ...CHAPTER 1 viii ISO Product Controller II and Hawkeye Operation Manual...
Страница 16: ...CHAPTER 1 6 ISO Product Controller II and Hawkeye Operation Manual...
Страница 22: ...CHAPTER 2 12 ISO Product Controller II and Hawkeye Operation Manual...
Страница 50: ...CHAPTER 4 40 ISO Product Controller II and Hawkeye Operation Manual...
Страница 92: ...APPENDIX A 82 ISO Product Controller II and Hawkeye Operation Manual...
Страница 95: ...P N 016 0171 584 H 85 FIGURE 3 Generic Cabling for Self Propelled Sprayer...
Страница 97: ...P N 016 0171 584 H 87 FIGURE 5 Generic Cabling for Pull Type Sprayer with Existing Raven CAN...
Страница 99: ...P N 016 0171 584 H 89 FIGURE 7 20 Spacing Generic Cabling...
Страница 111: ...P N 016 0171 584 H 101...
Страница 112: ...APPENDIX D 102 ISO Product Controller II and Hawkeye Operation Manual...
Страница 116: ...APPENDIX E 106 ISO Product Controller II and Hawkeye Operation Manual...
Страница 120: ...APPENDIX F 110 ISO Product Controller II and Hawkeye Operation Manual...
Страница 122: ...APPENDIX G 112 ISO Product Controller II and Hawkeye Operation Manual FIGURE 1 Hawkeye Screen Flow Tools Menu Softkey...
Страница 125: ...P N 016 0171 584 H 115 FIGURE 4 Hawkeye Screen Flow Tally Registers and Diagnostics Menu Softkeys...
Страница 127: ...P N 016 0171 584 H 117 FIGURE 6 Hawkeye Injection Screen Flow Product Setup Alarms and System Information...
Страница 128: ...APPENDIX G 118 ISO Product Controller II and Hawkeye Operation Manual...
Страница 134: ...APPENDIX H 124 ISO Product Controller II and Hawkeye Operation Manual...