WARNING
REASON
SOLVING
PELLETS FINISHED
ALARM
The pellet tank is empty
Check whether there are pellets in the tank
The ratiomotor does not load pellets.
Empty the tank to check that no objects have fallen inside which could prevent the correct
functioning of the screw
No pellet loading
Regulate the pellet setting
If the problem continues, contact the area Technical Assistance Centre.
BLACK - OUT
No electricity supply during working phase
Press the off button and repeat switching on the stove
If the problem continues, contact the area Technical Assistance Centre.
NO IGNITION ALARM
The pellet tank is empty.
Check if there are pellets inside the tank.
Setting of pellets and of intake during ignition phase insuf
¿
cient.
Contact local Technical Assistance Centre.
The resistance for lighting is defective of not in position
Contact local Technical Assistance Centre.
FLAME ANOMALY
ALARM
The pellet tank is empty.
Ceckis pellet is in the hopper
Bad setting of pellet and air on ignition in phase
Contact local Technical Assistance Centre.
EXTRACTOR REVS
ANOMALY ALARM
The revolution of smoke fan lowering morenthe 15% of speed to fan
congestion
Contact local Technical Assistance Centre.
ALARM FAN BROKEN
Smoke extractor encoder is not functioning or not correctly connected
Contact local Technical Assistance Centre.
No electricity supply to smoke extractor
Contact local Technical Assistance Centre.
The smoke extractor is blocked
Contact local Technical Assistance Centre.
DEPRESSION ALARM
The combustion chamber is dirty
Follow the cleaning operations of the stove as per the instructions in the booklet
The
À
ue is blocked
Check that the
À
ue is clear and clean
The vacuum switch is malfunctioning
Please contact local Technical Assistance Centre.
THERMAL SAFETY
DEVICE ALARM
The thermostat with manual reset has intervened
Reset the thermostat pressing the button on the back of the stove (see Fig. below).
The centrifugal fan is defective
Please contact local Technical Assistance Centre.
Combustion in the
¿
re pot is not optimal
Switch off the stove, clean the
¿
re pot and regulate combustion with the setting of the pellets.
If the problem continues, contact the area Technical Assistance Centre.
SMOKE
OVER-TEMPERATURE
ALARM
Combustion in the
¿
re pot is not optimal
Switch off the stove, clean the
¿
re pot and regulate combustion with the setting of the pellets.
The centrifugal fan is defective
Contact local Technical Assistance Centre.
If the problem continues, contact the area Technical Assistance Centre.
SMOKE SENSOR
ALARM
The smoke sensor is malfunctioning
Please contact the local Technical Assistance Centre
The smoke sensor has been disconnected from the board
Please contact the local Technical Assistance Centre
SCREW BLOCKAGE
ALARM
The screw is not loading the pellet.
Please contact the local Technical Assistance Centre
Unscrew the protection cap and
press the button to reset the
thermostat alarm.
12. DESCRIPTION OF ALARMS
By pressing the button P3 on the display, the alarm can be reset.
Try and repeat lighting after the cooling phase.