Spreading operation using the QUANTRON-K2 Control unit
77
5
5.4
Spreading with AUTO km/h operating mode
In AUTO km/h operating mode, the control unit automatically controls the position
of the metering slide based on the speed signal.
1.
Switch on the QUANTRON-K2 control unit.
2.
Make the spreading material settings:
Spreading density (g/m²)
Spreading width (m)
3.
Fill in the spreading material.
4.
Perform calibration for flow factor determination
or
Obtain the flow factor from the spreading material chart.
5.
Enter the flow factor manually.
6.
Press
Start/Stop
(also press the Enter key for HydroControl).
The spreading starts.
NOTICE
In order to achieve an optimum spreading result in the AUTO km/h operating
mode, a calibration is to be carried out before starting the spreading work.