C
HAPTER
2:
A
CCESSING
CC-SG
11
Power Down CC-SG
If a V1 unit loses AC power while it is up and running CC-SG, the V1 unit will remember its last
power state. Once AC power is restored, the V1 unit automatically reboots. However, if a V1 unit
loses AC power when it is powered off, the V1 unit will remain powered off when AC power is
restored.
Important: Do not hold the POWER button to forcibly power down CC-SG. The
recommended way to power down CC-SG is to use the following procedure.
To power down the CC-SG:
1.
Remove the bezel and firmly tap the
POWER
button. On G1 units, the
POWER
button is on
the back of the unit.
2.
Wait approximately one minute while CC-SG gracefully powers down.
Note: Users logged into CC-SG via Diagnostic Console will receive a short broadcast message
when the CC-SG unit is powered down. Users logged into CC-SG via a web browser or SSH will
not receive a message when the CC-SG unit is powered down.
3.
If you must remove the AC power cord, let the power down process finish completely before
removing the power cord. This is required for CC-SG to complete all transactions, close the
databases, and place the disk drives into a safe state for power removal.
Compatibility Matrix
The Compatibility Matrix lists the firmware versions of Raritan devices and software versions of
applications that are compatible with the current version of CC-SG. CC-SG checks against this
data when you add a device, upgrade device firmware, or select an application for use. If the
firmware or software version is incompatible, CC-SG displays a message to warn you before you
continue. Each version of CC-SG will only support the current and previous firmware versions
for Raritan devices at the time of release.
•
On the
Administration
menu, click
Compatibility Matrix
.
Figure 8 Compatibility Matrix
Содержание CC-SG
Страница 2: ...This page intentionally left blank...
Страница 26: ...12 COMMANDCENTER SECURE GATEWAY ADMINISTRATOR GUIDE This page intentionally left blank...
Страница 46: ...32 COMMANDCENTER SECURE GATEWAY ADMINISTRATOR GUIDE This page intentionally left blank...
Страница 158: ...144 COMMANDCENTER SECURE GATEWAY ADMINISTRATOR GUIDE This page intentionally left blank...
Страница 228: ...214 COMMANDCENTER SECURE GATEWAY ADMINISTRATOR GUIDE This page intentionally left blank...
Страница 236: ......
Страница 246: ...232 COMMANDCENTER SECURE GATEWAY ADMINISTRATOR GUIDE...
Страница 248: ...234 COMMANDCENTER SECURE GATEWAY ADMINISTRATOR GUIDE...
Страница 250: ...236 COMMANDCENTER SECURE GATEWAY ADMINISTRATOR GUIDE...
Страница 256: ...242 COMMANDCENTER SECURE GATEWAY ADMINISTRATOR GUIDE...