Administration
System Monitoring
SpycerNode
90
User Manual | 2902.3266.02 - 08
Monitoring through the Device Manager
The Device Manager monitors critical system components in realtime and
displays the gathered information.
The Health Panel for the SpycerNode provides both visual and statistics
details about the status of the system components. The panel can be
accessed by selecting the corresponding system and navigating to "Mainte-
nance > Health status".
File
OIDs
Object
Value
RS-SPYCER-
NODE-V1-MIB
.1.3.6.1.4.1.2566.127.1.4.
1.6.1.1.1.12.1.0
Chassis Fan 1
RPM (Rounds per minute)
.1.3.6.1.4.1.2566.127.1.4.
1.6.1.1.1.12.2.0
Chassis Fan 2
.1.3.6.1.4.1.2566.127.1.4.
1.6.1.1.1.12.3.0
Chassis Fan 3
[…]
[…]
.1.3.6.1.4.1.2566.127.1.4.
1.6.1.1.1.13.1.0
Chassis Temp 1
Temperature in °C
.1.3.6.1.4.1.2566.127.1.4.
1.6.1.1.1.13.2.0
Chassis Temp 2
.1.3.6.1.4.1.2566.127.1.4.
1.6.1.1.1.13.3.0
Chassis Temp 3
[…]
[…]
.1.3.6.1.4.1.2566.127.1.4.
1.6.1.1.1.14.1.4.0
Status
System disk
1
“OK”/“Critical“/“Not installed“
.1.3.6.1.4.1.2566.127.1.4.
1.6.1.1.1.14.2.4.0
Status
System disk 2
.1.3.6.1.4.1.2566.127.1.4.
1.6.1.1.1.14.3.4.0
Status
System disk 3
[…]
[…]
.1.3.6.1.4.1.2566.127.1.4.
1.6.1.1.1.10.1.3.0
Status PSU 1
“OK”/“Critical“
.1.3.6.1.4.1.2566.127.1.4.
1.6.1.1.1.10.1.3.0
Status PSU 1
Содержание SpycerNode 2U12
Страница 1: ...R S SpycerNode User Manual 2902 3266 02 08...
Страница 6: ...SpycerNode 6 User Manual 2902 3266 02 08...
Страница 82: ...Configuration Installing the Spectrum Scale Client SpycerNode 82 User Manual 2902 3266 02 08...
Страница 86: ...Operation Using the R S Device Manger SpycerNode 86 User Manual 2902 3266 02 08...
Страница 128: ...Working with the R S Installer RSI RSI Troubleshooting SpycerNode 128 User Manual 2902 3266 02 08...
Страница 132: ...Transport Packing the System SpycerNode 132 User Manual 2902 3266 02 08 5U Enclosures...
Страница 136: ...Index SpycerNode 136 User Manual 2902 3266 02 08...