Safety
11
User Manual | 2902.3266.02 - 08
General Notes
SpycerNode
General Notes
Please observe the following general important notes:
●
Do not lift the enclosure by the handles on the rear modules or the
PCMs. They are not designed to take the weight. Only lift from under-
neath the main chassis.
●
If this equipment is used in a manner not specified by the manufacturer,
the protection provided by the equipment may be impaired.
●
The optional RJ45 socket on the I/O module, it is for Ethernet connection
only and must not be connected to a telecommunications network.
●
All plug-in modules and blank plates are part of the fire enclosure and
must only be removed when a replacement can be immediately added.
The system must not be run without all modules or blanks in place.
●
Unplug the unit before you move it or if you think it has become
damaged in any way.
●
The plug on the power supply cord is used as the main disconnect
device. Ensure that the socket outlets are located near the equipment
and are easily accessible.
●
When powered by multiple AC sources, disconnect all supply power for
complete isolation.
●
In order to comply with applicable safety, emission and thermal require-
ments no covers should be removed and all bays must be populated with
plug-in modules or blanks.
●
The power connection should always be disconnected prior to removal of
a PCM/PSU from the enclosure.
●
A safe electrical earth connection must be provided to the power supply
cords. Check the grounding of the enclosure before applying power.
●
Provide a suitable power source with electrical overload protection to
meet the requirements laid down in the technical specification.
●
Do not remove PCMs, Cooling Modules, PSUs or I/O Modules unless
you have a replacement model of the correct type ready for insertion.
●
Connect the system to an uninterruptible power supply redundantly on
two phases.
●
It is recommended that you fit and check a suitable anti-static wrist or
ankle strap and observe all conventional ESD precautions when
handling plug-in modules and components. Avoid contact with backplane
components and module connectors, etc.
2U Enclosures
Please observe the following general important notes:
●
An enclosure can weigh up to to 26 kg (57lb) depending on configura-
tion. Do not try to lift the enclosure by yourself.
●
It is advisable to remove all plug-in modules to minimize weight before
lifting the enclosure.
●
The enclosure must only be operated from a power supply input voltage
range of 100-240 VAC.
Содержание SpycerNode 2U12
Страница 1: ...R S SpycerNode User Manual 2902 3266 02 08...
Страница 6: ...SpycerNode 6 User Manual 2902 3266 02 08...
Страница 82: ...Configuration Installing the Spectrum Scale Client SpycerNode 82 User Manual 2902 3266 02 08...
Страница 86: ...Operation Using the R S Device Manger SpycerNode 86 User Manual 2902 3266 02 08...
Страница 128: ...Working with the R S Installer RSI RSI Troubleshooting SpycerNode 128 User Manual 2902 3266 02 08...
Страница 132: ...Transport Packing the System SpycerNode 132 User Manual 2902 3266 02 08 5U Enclosures...
Страница 136: ...Index SpycerNode 136 User Manual 2902 3266 02 08...