Remote-Control Commands
R&S
®
SMCVB-K164
99
User Manual 1179.0974.02 ─ 02
Example:
See
Example "Configuring mode and stream parameters"
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:BB:T2DVb:PLP<ch>:IBS:B?
Queries the in-band signaling type B state.
Query requires L1 T2 specification version higher than V1.1.1, see
Return values:
<IBSB>
0 | 1 | OFF | ON
*RST:
0
Example:
See
Example "Configuring mode and stream parameters"
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:BB:T2DVb:PLP<ch>:ID
<PlpId>
Sets the PLP ID. The PLP ID has to be unique.
Parameters:
<PlpId>
integer
Range:
0 to 255
*RST:
0
Example:
See
Example "Configuring mode and stream parameters"
Manual operation:
See
[:SOURce<hw>]:BB:T2DVb:PLP<ch>:ISSY?
Queries the
Return values:
<Issy>
OFF | SHORt | LONG
OFF
ISSY is not active. ISSY indicator field is 0.
SHORt
ISSY is active. ISSY indicator field is 1. The synchronizer uses a
short
.
LONG
ISSY is active. ISSY indicator field is 1. The synchronizer uses a
long
.
Mode and Stream Commands