Return values:
<OfdmSymbolDur>
float
Range:
0 to 0.010000
Increment: 0.000001
*RST:
0
Example:
See
Example "Querying frame and symbol duration information"
Usage:
Query only
Manual operation:
See
6.8.2
L1 Signaling Commands
Example: Querying L1 signaling parameters
:SOURce1:BB:T2DVb:INFO:PREBits?
// Response: "200"
// L1-pre singnaling length is 200 bit.
:SOURce1:BB:T2DVb:INFO:PRECells?
// Response: "1800"
// L1-pre singnaling length is 1800 cells.
:SOURce1:BB:T2DVb:INFO:POSBits?
// Response: "350"
// L1-post singnaling length is 350 bit.
:SOURce1:BB:T2DVb:INFO:POSCells?
// Response: "250"
// L1-post singnaling length is 250 cells.
Commands
[:SOURce<hw>]:BB:T2DVb:INFO:POSBits?
..................................................................... 127
[:SOURce<hw>]:BB:T2DVb:INFO:POSCells?
................................................................... 128
[:SOURce<hw>]:BB:T2DVb:INFO:PREBits?
..................................................................... 128
[:SOURce<hw>]:BB:T2DVb:INFO:PRECells?
................................................................... 128
[:SOURce<hw>]:BB:T2DVb:INFO:POSBits?
Queries the L1-post signaling length in bits.
Return values:
<L1PostSigBits>
integer
Range:
0 to 262175
*RST: