Remote-Control Commands
R&S
®
SMCVB-K164
108
User Manual 1179.0974.02 ─ 02
[:SOURce<hw>]:BB:T2DVb:LDATa
<DataSymbols>
Sets the number of data symbols per T2
frame.
Parameters:
<DataSymbols>
integer
Range:
0 to 4095
*RST:
59
Example:
See
Example "Configuring OFDM parameters"
Manual operation:
See
"Data Symbols per T2 Frame (L_DATA)"
[:SOURce<hw>]:BB:T2DVb:LF?
Queries the computed number of OFDM symbols per T2
frame.
Return values:
<OfdmSymbols>
integer
Range:
0 to 4095
*RST:
4
Example:
See
Example "Configuring OFDM parameters"
Usage:
Query only
Manual operation:
See
"OFDM Symbols per T2 Frame (L_F)"
[:SOURce<hw>]:BB:T2DVb:NSUB
<Subslices>
Sets the number of subslices per T2
frame.
Parameters:
<Subslices>
integer
Range:
0 to 32767
*RST:
1
Example:
See
Example "Configuring OFDM parameters"
Manual operation:
See
"Subslices per T2 Frame (N_SUB)"
[:SOURce<hw>]:BB:T2DVb:NT2Frames
<NT2Frames>
Sets the number of T2
frames per super frame.
Parameters:
<NT2Frames>
integer
Range:
2 to 255
*RST:
2
Example:
See
Example "Configuring OFDM parameters"
Manual operation:
See
"T2 Frames per Super Frame (N_T2)"
OFDM Commands