Remote-Control Commands
R&S
®
SMCVB-K164
105
User Manual 1179.0974.02 ─ 02
Manual operation:
See
[:SOURce<hw>]:BB:T2DVb:PLP<ch>:TIL:FINT
<FrameInterval>
Defines the time interleaver frame interval (I
Jump
).
For limitations, see specification
Parameters:
<FrameInterval>
integer
Range:
1 to 255
*RST:
1
Example:
See
Example "Configure BICM parameters"
Manual operation:
See
[:SOURce<hw>]:BB:T2DVb:PLP<ch>:TIL:LENGth
<TILLength>
Defines the time interleaver length within the time interleaving frame.
For limitations, see specification
Parameters:
<TILLength>
integer
Range:
0 to 255
*RST:
3
Example:
See
Example "Configure BICM parameters"
Manual operation:
See
[:SOURce<hw>]:BB:T2DVb:PLP<ch>:TIL:TYPE
<TILType>
Defines the time interleaver type.
Parameters:
<TILType>
integer
0
Maps each interleaving frame directly to a T2
frame.
1
Maps each interleaving frame to more than one T2
frame.
Range:
0 to 1
*RST:
0
Example:
See
Example "Configure BICM parameters"
Manual operation:
See
BICM Commands