Network and Remote Operation
R&S
®
FSPN
289
User Manual 1179.4363.02 ─ 01
buffer use the "Clear Error List" button. It is automatically cleared when the R&S
FSPN
is shut down.
The following information is available:
No
Device-specific error code
Error
Brief description of the error
Date/Time
Time the message occurred
Remote command:
Clear Error List
Deletes the error message buffer for remote operation.
Note:
The remote error list is automatically cleared when the R&S
FSPN is shut down.
Remote command:
10.3.6
Returning to Manual Mode ("Local")
When switched on, the instrument is always in the manual measurement mode and
can be operated via the front panel. As soon as the instrument receives a remote com-
mand, it is switched to the remote control mode.
In remote control mode, all keys of the instrument except the [PRESET] key are dis-
abled. The "LOCAL" softkey and the
softkey are displayed.
Local
The instrument switches from remote to manual operation.
Note:
●
If the local lockout function (
LLO
) has been activated in the remote control mode,
manual operation is no longer available until
GTL
is executed.
●
Before you switch back to manual operation, all remote command processing must
be completed. Otherwise, the instrument will switch back to remote control immedi-
ately.
●
If you select the "Local" softkey while a self-alignment or a self-test is still running
(which was started remotely), the instrument only returns to the manual operation
state when the alignment or test is completed.
Furthermore, when you return to manual operation, the following happens:
●
All front panel keys are enabled.
●
The main softkey menu of the current mode is displayed.
●
The measurement diagrams, traces and display fields are displayed again.
●
If, at the time of pressing the "LOCAL" softkey, the synchronization mechanism via
*OPC
,
*OPC?
or
*WAI
is active, the currently running measurement procedure is
aborted and synchronization is achieved by setting the corresponding bits in the
registers of the status reporting system.
●
Bit 6 (User Request) of the Event Status Register is set.
Network and Remote Control Settings