www.raisecom.com
User Manual
72
5. Sub-Board Slot Number of line 2
6. Channel Select of line 2
7. Auto-negotiation Set of line 2
8. Default Port Mode of line 2
9. Reset Ether Net Port
Sub-card 1 (double lines Ether Net Board) Set Command:1-9, Menu Display: M, Return: Q Command:
Note
: the command explanation is available in
A.19 Ethernet data sub-card setting menu.
The showing menu for the other type of sub-card may be developed in future:
1. Sub-card time slot number
2. Mode 0 Set
3. Mode 1 Set
4. Byte 1 Set
5. Byte 2 Set
Sub-card 1 (unnamed board) Set Command:1-5, Menu Display: M, Return: Q Command:
Note
: the command explanation is available in
A.20 Undefined sub-card Set.
A.9.9 DCD and CTS of V35V24 Board with Alarm Set
In System Setting menu press number key 9 to configure the alarm correlation of DCD & CTS:
With Alarm Set: Enable
In this status use
→
key to change the configured value; Press ENTER to confirm configuration,
press E key to finish configuration, and ESC to cancel configuration.
When disable alarm correlation function, if the output status of DCD & CTS is normal the V35 board
will transmit data and remote DTE device does not need to reset all the time; when enable alarm
correlation function, if there are alarms of LOS, LOF and AIS, status of DCD will be unready and if
there is RAL alarm status of CTS will be unready.
A.10 Line Board Setting menu
This section we will explain how to configure RC3000-OPT line-board and you must first enter the
Line Board Setting menu.
A.10.1 Alarm Mask Set
In optical line-board setting menu press number key 1 to configure optical alarm mask:
Optical Alarm Mask Set:
Local Optical Loss: Mask (Enable)
In this status use
→
key to disable or enable alarm mask; use
↓↑
to change items (alarms); Press
ENTER to confirm configuration, press E key to finish configuration, and ESC to cancel