www.raisecom.com
User Manual
53
EEPROM Set:
Line-Board Type:2E1 Board
Device Query Command:1-8, Menu Display: M, Return: Q Command:
Please refer to Line-Board information (RAM) for Line-Board information explanation.
A.4.4 E1 using and mode information
In device set query menu press number key
4
, and there will be E1 using and mode information:
E1: First Second Third Fourth
Real information:
Use: 1=Using 1 1 1 0
Mode: 1=PCM31 0 0 0 0
Mask: 1=Mask 1 1 0 0
APS: Enable
EEPROM Set:
Use:1=Using 1 1 1 0
Mode:1=PCM31 0 0 0 0
Mask:1=Mask 1 1 0 0
APS: Enable
Device Query Command: 1-8, Menu Display: M, Return: Q Command:
There are two parts information, one is the information saved in RAM and the other part is the
information saved in EEPROM.
A.4.5 Clock, CRC and Net information, version setting:
In device set query menu press number key
5
, and there will be E1 using and mode information:
Real information:
Clock Mode: Master Clock Auto
Net Topology: Three E1 Direction
Net Using Time Slot: 0 Time Slot
CRC Transmit: Enable
Alarm Sound Output: Enable
Work
mode
of
VER
A:
Enable
10-line mode setting: enable
EEPROM information:
Clock Mode: Master Clock Auto
Net Topology: Three E1 Direction
Net Using Time Slot: 0 Time Slot