www.raisecom.com
User Manual
93
A.25.6 Make Default Set
In operate menu press number key 6 to restore factory default value:
Run this command, the device will be first state from manufactory.
All saving data will loss. The device will restart.
Run this command(Y/N):
All information in EEPROM will be invalid if you press Y key, and press N key will exist. By
default, except hardware version there is no information in EEPROM. So restore to factory default
value is same as delete all saved information.
A.25.7 Clear Reset and Card-Change Flag
In operate menu press number key 7 to clear flag information of resetting device and changing the
card. And there is no prompt.
A.25.8 Test Watchdog
In operate menu press number key 8 the check whether watchdog can reset CPU. Normally
watchdog program will restart CPU, and in abnormal status the system cannot exist from
closed-loop.
A.25.9 Test EEPROM
In operate menu press number key 9 to test whether EEPROM can save data normally:
Normally there will be:
Can save data to EEPROM.
Abnormally there will be:
Can not save data to EEPROM.
A.26 Version
In main menu press number key 7 to get version information:
1.Display Version information
Version Information
Command: 1-1, Menu Display: M, Return: Q Command:
A.26.1 Display Version information
In version menu press number key 1 to show device version information:
Hardware Version: REV A.01
Software Version: REV 1.1
PCB Version: REV A.3