3.0 Mounting and Installation
Rain Master Eagle User Manual
- 22 -
After completing the physical installation of the flow sensor, make the necessary wiring connection
from the flow sensor to the Rain Master Eagle controller as follows:
1. TURN THE POWER OFF AT THE CONTROLLER.
2. At the Flow Sensor:
• Connect the BLACK wire of the Flow Sensor to the BLACK wire of the “EVCAB-SEN”
sensor cable.
• Connect the WHITE wire of the Flow Sensor to the WHITE wire of the “EV-CABSEN”
sensor cable.
* Use the weatherproof wire nut connectors provided with the Flow Sensor to make the
splice.
3. At the Rain Master Eagle controller:
• Connect the BLACK wire of “EV-CAB-SEN” cable to Pin 4 (FLOW-) of the Rain Master
Eagle Controller.
• Connect WHITE wire of “EV-CAB-SEN” to Pin 3 (FLOW+) of the Rain Master Eagle
Controller.
4. Turn POWER ON at the Controller.
5. Using the SETUP key, enable the Flow Sensor and select the pipe size for the Flow Sensor
installed.
3.2.3 Sensor Wiring
The Rain Master Eagle controller supports most modern 2-wire Rain or Moisture sensor
configurations.
The 2 wire sensors are connected to pins 1 and 2 on the sensor connector, as depicted in Figure 11
– Sensor Interface Electrical Connections.
Figure 11 – Sensor Interface Electrical Connections
INPUT (SILVER)
24VAC (COPPER)
ET – (WHITE WITH
BLUE STRIPES)
ET + (BLUE)
+ (WHT)
– (BLK)
Rain
Sensor
Flow
ET
1 2 3 4 5 6
Содержание RME EAGLE EG Series