5.0 FUNCTION AND EXECUTION KEY OPERATIONS
Rain Master Eagle User Manual
- 48 -
5.8 SKIP DAYS FUNTION KEY
SKIP
DAYS
Usage
: The SKIP DAYS key is used to select a watering schedule based on a thirty-day (30) cycle.
The thirty-day irrigation cycle is selectable on an individual irrigation program basis, you enter the
days between watering cycles and the number of days before the cycle is to start.
Press the SKIP DAYS key; the controller prompts for the number of days between watering cycles
(SD = Skip Days) press DATA ENTRY keys 1 – 30, and then press ENTER. The controller will
then prompt for the days before the start of the cycle (LFT = Days Left) press DATA ENTRY keys
0 - 30 and then press ENTER to complete the action.
If you wish to terminate the Skip Days process at any point, press the QUIT key to return to the
Automatic Mode.
EXAMPLE
: In Program number four (4), set the Controller to water every fourteen (14) days and
the cycle will start tomorrow.
Press:
SKIP
DAYS
Controller will display:
4 SD -
Press:
ENTER
Controller will display:
4 LFT -
Press:
ENTER
EXAMPLE
: In Program number one (1), set the Controller to water every other day and have the
cycle start tomorrow.
Press:
SKIP
DAYS
Controller will display:
1 SD -
Press:
ENTER
Controller will display:
1 LFT -
Press:
ENTER