Rain Master Eagle User Manual
6.0 Setup Key Operations
- 71 -
6.13.7.2 Setting Station Limits
This feature allows you to directly set a station’s upper flow limit to any value. It is an alternative to
using the LEARN mode described above. In this feature each station limit is set one at a time.
To use this feature:
1. Successively press SETUP until you see LIMITS in the display.
2. Press the station number followed by ENTER.
3. You now have the opportunity to set the upper flow limit in one of two ways. Pressing the
MANUAL key will toggle between them.
• You can explicitly put in the limit followed by ENTER.
• You can press MANUAL and the controller will start watering the station. During this time
the flow rate will be displayed on the left and the limit will be displayed on the right. By
pressing ENTER you can accept the flow rate as the limit (adjusted by the flow percentage):
The limit can be set to from 0 to 500 GPM. The set limit will be rounded to the nearest
2, so if you set the limit to 55, when you review the setting it will be 54.
EXAMPLE
: Set the upper station flow limit of Station 15 to 44 GPM.
Continue to press:
SETUP
Until display indicates:
l im its
Press:
ENTER
Display will indicate:
15 - 200
Press:
ENTER
Display will indicate:
L Im its
You can now continue to enter limits for other stations, when complete,
Press:
QUIT
The controller will return to the Automatic Mode.