Rain Master Eagle User Manual
5.0 FUNCTION AND EXECUTION KEY OPERATIONS
- 31 -
5.0 FUNCTION AND EXECUTION KEY OPERATIONS
The Rain Master Eagle controller is capable of running conventional irrigation programs, as well as
sophisticated Evapotranspiration (ET) based irrigation programs. The Rain Master Eagle controller
utilizes inputs provided by weather sensors; Internet provided adjustment factors, and Historical
trend data that were derived from years of weather data collection and analysis.
In this section of the manual we will explore the use of the Rain Master Eagle in the roll of a
conventional irrigation controller. Conventional irrigation is programs that have been entered by
you. They do not change or adjust automatically due to changes in the weather conditions. The
Rain Master Eagle controller will store and execute these entered programs without fail for as long
as you may wish.
In Chapter 60 - SETUP Key Operations of the manual we will expand the knowledge and
experience gained here to utilize additional features of the Rain Master Eagle Controller, including
the use of water measurement sensors and irrigation control methods.
In Chapter 70 - ET Key Operations and Chapter 80 - ET Programming of this manual we will
explore the features of Evapotranspiration program control. Your Rain Master Eagle Controller is
capable of interfacing to weather sensors and will automatically adjust watering cycles due to hot
and windy days and changes in the seasons (from Summer to Fall to Winter). Theses Chapters will
cover water conservation methods using the state-of-the-art technology of your Rain Master Eagle
Controller.
5.1 PROGRAM FUNCTION KEY
PROGRAM
Usage
: The PROGRAM key is used to select the program you want to enter, modify or review.
Once selected, you need not change the Program Number until you want to enter or review
information in a different program. The Rain Master Eagle Controller has four (4) programs
available for your use. They are referred to as 1, 2, 3, and 4.
You may clear all information in a program using this function. To select a program press the
PROGRAM key; press keys 1 – 4 for the program number, then press ENTER to complete the
selection.
While programming other functions of the controller, the selected program number is displayed as
a convenience.
EXAMPLE
: Select Program Number 2.
Press
:
PROGRAM
ENTER
The controller will return to the Automatic Mode.