3.0 Mounting and Installation
Rain Master Eagle User Manual
- 18 -
Figure 7 – Master Valve and Pump Electrical Connections with Isolation Relay
!
ALWAYS TURN-OFF POWER before changing or modifying field, sensor or power
wiring within the controller. Dangerous voltage and current exist within the controller
which may damage the controller if improperly connected or shorted
.
3.2.1.2.2 Independent Use - Normally Closed Master Valve and Pump
If you use a Master Valve which requires activation to open, and a pump which is periodically
needed for irrigation, connect the Master Valve Solenoid to the MV and the Master Valve
Common terminals and the Pump starter wire to the Station 1 terminals.
If the Pump starter DOES NOT operate on 24 VAC or the combination of the Master Valve
Solenoid and Pump starter running together uses more than 1 Ampere of current, you will need an
isolation relay (RMIS part # RLY1 or equivalent) as depicted in Figure 8 - Independent Control of
Master Valve and Pump using Isolation Relay. During configuration SETUP, select the Normally
Closed (NC) Valve type for all programs which require the Master Valve and select Pump
operation for all programs which require the pump.
If more than one Rain Master Eagle controller will control the Master Valve and Pump, the
controllers must be isolated from one another. Contact your local distributor or Rain Master
Irrigation Systems for a pamphlet on multiple controller installations (RMIS Technical Bulletin
018).
Yellow
Yellow
White
Pump
Black
to Transformer
Master Valve
Relay1