The system now supports the smart-UPS function provided by the American Power Conversion Corp.
(APC) UPS of other suppliers are acceptable but without the related setup function.
UPS Type
Select types of UPS. For APC UPS please select Smart-UPS or None for
any other one.
Shutdown Battery
Level (%)
The system shuts down automatically when battery capacity is lower than
given limits. Set the limit value to zero to shut down your UPS.
Shutdown Delay (s)
In case of power failure and it lasts longer than the delay seconds of power
off the system shuts down automatically. Set the value to zero to turn off this
function.
Shutdown UPS
Select ON to power off your UPS after successful system shut down in case
of power failure. After the power supply resumes the system will be turn on
after the UPS is initiated. Select OFF to stop all the above actions.
Status
Status of UPS:
“Detecting…”
“Running”
“Unable to detect UPS”
“Communication lost”
“UPS reboot in progress”
“UPS shutdown in progress”
“Batteries failed. Please change them NOW! ”
Battery Level (%)
Remaining battery power in percentage.
3.7 System maintenance
The Maintenance function helps you do preliminary troubleshooting with simple viewing and operation
in case of system failure. Available functions are: System information, Upgrade, SAS, Reset to factory
default, Import and export, Event log and Reboot and shutdown.
Figure 3.7.1
3.7.1 System information
Select System information for viewing current system information including: Model No., CPU Type,
Installed system memory, Controller serial no. and Backplane ID.
Introduction to the GUI
39