RADWIN 5000 SCB Jet User Manual
Release 4.2
4-16
Step 7: Connect the HBS/HSU to the PoE device
Hardware Installation
Figure 4-29: Exposing the tacky side of the sealing tape
3. After connecting a cable to a unit, tighten the cable gland cap firmly and use the
insulation tape to fully cover the cable gland.
Figure 4-30: Waterproofing an external connection
External Ports for CAT-5e Cables
All external ODU ports should be water sealed. Use the same materials and method as for the
LPU cable glands.
4.5.7 Step 7: Connect the HBS/HSU to the PoE device
Connect the HBS/HSU to the LAN-Out port only. It will not work on the LAN-In port.
4.5.8 Step 8: Connect the PoE Device to a Network
Connect the PoE to network equipment such as a switch from the LAN-In port. Connecting
network equipment to the LAN-Out port may damage it.
4.5.9 Step 9: Power up the HBS/HSU from a Poe Device
Connecting the HBS/HSU port labelled PoE to a powered up PoE is sufficient.