RADWIN 5000 SCB Jet User Manual
Release 4.2
4-5
Hardware Installation Procedure
Hardware Installation
•
Cable ties
•
Sealing material
•
Waterproofing tape such as Scotch 23 Tape ¾” wide, from 3M to ensure IP-67 compli-
ant protection against water and dust
•
ODU grounding cable 10 AWG
•
ODU-PoE cable (outdoor class, CAT-5e, 4 twisted pairs, 24AWG):
•
Up to 100 m. for 100BaseT connection.
•
For a 1000BaseT connection (HBS only) use an ODU-PoE cable no longer than 75m.
•
External CAT-5e cable diameter should be between 7-9 mm to ensure waterproof
sealing.
4.5 Hardware Installation Procedure
After reading the Safety and
Kit Contents
sections and doing the preparations in
Preparations Before You Start
, follow the instructions in this section
in the order indicated
to
install your RADWIN 5000 SCB Jet unit.
Place a checkmark in the “Done?” column once the task is completed:
4.5.1 Step 1: Unpack and Check Shipped Items
For each of the items below, do the following:
1. Remove the equipment from the box.
For 1000BaseT, use RADWIN supplied ODU-PoE cables, which guarantees
1Gb performance. RADWIN cannot guarantee 1Gb performance if you
use third party cables.
Table 4-1: Hardware Installation Workflow: Checklist
Step
Subject
Page
Done?
1.
Step 1: Unpack and Check Shipped Items
4-5
2.
Step 2: Mount the HBS/HSU
4-6
3.
Step 3: Ground the HBS/HSU
4-10
4.
Step 4: Install a PoE device
4-11
5.
Step 5: Mount the Lightning Protection Units
4-11
6.
Step 6: Add Supplemental Waterproofing
4-15
7.
Step 7: Connect the HBS/HSU to the PoE device
4-16
8.
Step 8: Connect the PoE Device to a Network
4-16
9.
Step 9: Power up the HBS/HSU from a Poe Device
4-16