Bus Error Function
The internal time-out value (BERRINT) can be altered by changing the settings of
jumpers BR26 and WK1/WK2. The initial timing is set by WK1/WK2, BR26 alters this
value by a factor of 10.
The other jumpers involved in the chain must be left in their default positions,
i.e.
BR27 # 1 to # 2
BR28 # 1 to # 2 and # 3 to # 4
WK1# 1 to WK1# 2
Table 24 lists possible time-out values and the jumper settings required. Figure 41
shows the location of the jumper fields.
Table 24 Time-Out Counter Settings
BR26
1 - 2 (E)
2 - 3 (CL8)
WK1 # 3 to WK2 # 3
250
m
5P255Ds 25
m
s
WK1 # 2 to WK2 # 2
320
m
s
32
m
s
WK1 # 4 to WK2 # 4
2.5ms**
250
m
s
** is the default setting
For example, to set BERRINT to 25
m
s the jumpers must be set as follows:
WK1 WK2
BR26
1 o
o 1
o
o
o
2 o
o 2
1
2
3
3 o
o 3
4 o
o 4
PME68-1B Manual
Page 73 Issue 5