Interrupt Handling
ACFAIL Interrupt
The position of the ACFAIL jumper field is BR20, shown on the location diagram Fig-
ure 30.
The pins of BR20 are connected as follows:
BR20
Connected to
1
ACFAIL* (from Receiver)
2 IRQ6
3
HALT (of 68000 CPU)
If a connection is made between pins 1 and 3, the on-board CPU will stop all activities
immediately after the ACFAIL signal is asserted. The Red HALT LED on the front
panel will light.
Figure 30 Location of the ACFAIL Jumper Field
If the link is removed, ACFAIL will have no effect.
BR20
3
2
1
J76
BAT
.
PME68-1B Manual
Page 65 Issue 5