RTC Interrupts
The RTC interrupt level is selectable between:
RTC interrupt
or
PIT PC3 interrupt
These options are set by LK60 and B200
LK60
B200
RTC only
2-3
IN
PIT PC3 only
1-2
IN
*
Figure 27 Location of the RTC Jumper and RTC Chip.
J63
B200
1
2
J51
3
2
1
LK60
BAT
* NOTE.
PIT PC3 by default
interrupts on level 6; so
for this combination
BR18 Pin 2-3 should be
removed. (See Figure 28)