Figure 12 Bus Grant Daisy Chain
Bus Release Functions
Two release functions are defined in the VMEbus specification:
RWD Release When Done
ROR Release On Request
The PME68-1B provides a RAT (Release After Time-Out) function and, when config-
ured in slave arbitration mode, a release on BCLR.
The maximum continuous time available as bus master is defined by on-board jumpers
as 30, 60 or 300
m
s. An arbitration cycle on every bus cycle can also be selected. Refer to
Chapter 4 for further details.
1
1
1
1
a
b
c
c
b
a
c
b
a
c
b
a
Slot 1
Slot 2
Slot 3
Slot n
4
5
6
7
8
9
10
11
Pin 4 b
= BG0IN*
Pin 5 b
= BG0OUT*
Pin 6 b
= BG1IN*
Pin 7 b
= BG1OUT*
Pin 8 b
= BG2IN*
Pin 9 b
= BG2OUT*
Pin 10 b
= BG3IN*
Pin 11 b
= BG3OUT*