Off-Board Arbitration
In a four level bus arbitration scheme with an external arbiter, the bus request levels
require the following connections: (See Figure 33 for positions of WB1, WB2,
WI1# /2/3/4)
BR0*
BR2*
WB1# 1 to WB1# 2
WI2# 3 to WI3# 1
WB1# 1 to WB1# 4
WI1# 3 to WI4# 3
WI1# 1 to WI2# 3
WI2# 2 to WI3# 2
WI1# 1 to WI2# 1
WI2# 2 to WI3# 2
WI4# 2 to WI3# 3
WI1# 3 to WI4# 3
WI4# 2 to WI3# 1
WI2# 3 to WI3# 3
BR1*
BR3*
WB1# 1 to WB1# 3
WI2# 1 to WI3# 1
WB1# 1 to WB2# 1
WI2# 1 to WI3# 1
WI1# 1 to WI2# 2
WI1# 3 to WI4# 3
WI1# 1 to WI1# 3
WI2# 2 to WI3# 2
WI4# 2 to WI3# 2
WI2# 3 to WI3# 3
WI4# 2 to WI4# 3
WI2# 3 to WI3# 3
Bus-Release Functions
PME68-1B provides for a RAT (Release After Time-Out) function and in slave arbitra-
tion mode, release on BCLR.
The maximum continuous time available as bus master is defined by the setting of
jumper fields WL1 and WL2 (BR32 must be closed). The location of these jumpers is
shown in Figure 35.
Time Out (typical)
Connected Between
30
m
s
WL1# 1 WL2# 1
60
m
s
WL1# 2
WL2# 2
300
m
s
WL1# 3
WL2# 3 (Default Setting)
If WL2# 1 is connected to WL3# 1, every transfer on the VMEbus causes an arbitration
cycle.
Figure 35 Location of Bus Release Time Jumpers
WL2
WL1
1 2 3
2
1
BR32
PME68-1B Manual
Page 68 Issue 5
Содержание PME 68-1B
Страница 8: ...Figure 1 The PME 68 1B Board Photograph not available in PDF PME 68 1B Manual Page 2 Issue 5...
Страница 12: ...Figure 4 Component Layout Diagram P5 P4 P3 BAT PME 68 1B Manual Page 6 Issue 5...
Страница 56: ...Figure 14 Link Areas BAT PME68 1B Manual Page 50 Issue 5...
Страница 57: ...Blank Page PME68 1B Manual Page 51 Issue 5...
Страница 59: ...Figure 15 Location of System EPROM Area 1 2 3 4 1 2 3 4 WC1 WC2 PME68 1B Manual Page 53 Issue 5...
Страница 80: ...Figure 41 Location of BERR Jumpers 1 2 3 4 WK1 WK2 BR26 2 3 1 BAT PME68 1B Manual Page 74 Issue 5...
Страница 132: ...Blank Page PME68 1B Manual Page 126 Issue 5...