RX Status
Rqly Portion of Telemetry screen
Here you can configure the threshold for the RX alarms. The Rx-Stats label will change (Rx-Stats, RSSI, Rqly,
Sgnl) depending on the protocol that is used with the model.
•
Low alarm
- The threshold value when the "RF signal low" voice prompt will be played. The recommended
value is 45.
•
Critical alarm
- The threshold value when the "RF signal critical" voice prompt will be played. The
recommended value is 42.
•
Disable telemetry alarms
- When enabled, no alarm voice prompts will be played.
Variometer
A variometer detects changes in the model altitude. EdgeTX can alert the user of these altitude changes by
providing a rising/lower pitched tone. Use the
Variometer
menu on the Radio Setup page to set the actual
frequency and volume of the tone to be played. The following options exist to configure the variometer
alarm.
You will need to use a
Vario
Special or Global Function to enable this functionality!
•
Source
- Specifies the sensor to use as the variometer. It is selected from the telemetry sensors added in
Sensors
section.
•
Range
- Specifies the ascent/descent range that will trigger the change in the Variometer beeping pitch. If
climb/descent rate is within the range specified here, beeping pitch will change according to that value.
When it goes beyond the range specified here, beeping pitch will stop changing. Units are meters/second or
feet/second based on the
Units
setting on the
Radio Setup
page.
•
Centre
- Specify the range for ignoring changes in climb/descent rates. When the climb/descent rate is within
the range specified here, the beeping pitch will not change.
•
Tone/Silent
- Specifies whether to beep when climb/descent rate is within the range specified by
Centre
.
8.2. Sensor Configuration
Sensor Configuration page
The below options can be configured for sensors:
•
Name:
Name of the sensor - up to 4 characters.
Содержание MT12
Страница 5: ...1 3 Radio overview...