Outputs Configuration page
The output configuration screen has the following configuration options:
•
Name
- Name for the Output up to 6 characters.
•
Subtrim
- The subtrim value (max 100). It can also be set to a global variable by pressing the ldong-pressing
the
[Enter]
button to switch to GV Mode and then selecting the desire global variable.
•
Min
- Minimum output limit. Commonly used to prevent servo binding on models that use servos for the
control surfaces.
•
Max
- Maximum output limit. Commonly used to prevent servo binding on models that use servos for the
control surfaces.
•
Direction
- Select
---
for normal output value,
INV
if you want to invert the output value.
•
Curve
- Specify the custom curve (in any) that you want to use for this output. See
Curves
for more
information about custom-defined curves.
•
PPM Center
- Specify the pulse-width value for the center value of the output channel (between 1000 -
2000). Changing this will shift the entire output range, including upper and lower limits.
•
Subtrim mode
- Defines how the subtrim value affects the min/max output values. There are two options:
o
△
(Center Only)
- Only the center value shifts. The upper and lower limits do not change. The
reaction of the stick differs between the upper half and the lower half from midpoint.
o
= Symmetrical
- Both the upper and lower limits will shift according to the shift of the center value.
The reaction of the stick is the same on both sides of the midpoint.
4.
Curves
5.1 Setting curves
The
Curves
screen allows you to define custom curves to use in the Inputs, Mixes, or Output screens. The
curves screen will show the configured custom curves, with a graphical representation of each curve.
Curves Screen
Selecting one of the curves or empty curve slots will open the configuration page for that curve.
Curves Configuration Screen