User Manual 3162A/B
Using The Instrument 3-12
HOP Mode
In HOP mode, the generator outputs a pre-selected waveform whose frequency
(or sample clock setting) is determined by the HOP table and HOP control
lines. The Model 3162B hops from frequency to frequency according to a pre-
determined table. The hop table contains hop numbers and their associated
dividing ratios. The hop table holds up to 256 hop settings.
The WaveCAD Hop Table editor (shown below) is an example of a graphical
interface for defining a hop table.
Figure 3-3, WaveCAD Hop Table
The following low-level commands programs a five-step hop table:
FREQ:HOP 1,50
FREQ:HOP 2,500
FREQ:HOP 3,5000
FREQ:HOP 4,50000
Each trigger advances the output to the next frequency. In the above example,
setting the sample clock to 200MHz generates the following hop frequencies:
200MHz, 40MHz, 4MHz, 400kHz, and 40kHz. If the trigger lines are used as
the hop advance sources, the sequence will repeat itself continuously. By
selecting the D-Sub connector as the hop advance source, any external hop
pattern may be used. Undefined hop table entries have a dividing ratio of 1.
Note that the hop command does not have a query.
The command:
Содержание 3162A/B
Страница 4: ...This page was left intentionally blank...
Страница 10: ...3162A B User Manual vi Support Offices 6 2...
Страница 12: ...3162A B User Manual viii This page was left intentionally blank...
Страница 17: ...User Manual 3162A B Getting Started 1 5 Figure 1 2 The Front Panel...
Страница 23: ...User Manual 3162A B Getting Started 1 11 Figure 1 7 WaveCAD Example...
Страница 27: ...User Manual 3162A B Getting Started 1 15 This page was left intentionally blank...
Страница 28: ......
Страница 34: ...3162A B User Manual Configuring The Instrument 2 6 This page was left intentionally blank...
Страница 78: ......
Страница 134: ...User Manual 3162A B Maintenance and Performance Checks 5 32 This page was intentionally left blank...