User Manual 3162A/B
Using The Instrument 3-7
The query:
APPLy:<function_shape>?
queries parameters associated with the specified function shape, and returns
a string of values depending on the parameters that are available for the
selected function shape.
The query:
APPLy?
queries parameters associated with the currently selected function shape and
returns a string of values depending on the parameters available for the
selected function shape. For example, if the generator is programmed to output
a ramp waveform, the APPL? command returns: "1e+6, 2, 0 , 0, 10, 10, 10".
Example 2
The following example programs the Model 3162B using the APPLy command.
This example turns on the main output, generates a square waveform,
programs frequency to 2MHz, programs amplitude to 1V and offset to 1V. It
also changes the square wave duty cycle parameter to 25%.
/* Reset the Model 3162B to its default condition as listed in Table 3-1. */
:RESet;
/* Change the output waveform to square, frequency to 2MHz, amplitude to 1V,
offset to 1V and duty cycle to 25%. Note that there is no need to use the
FUNC:MODE command because the default value after RESet is FIXed. */
:APPLy:SQUare 2e6,1,1,25
/* Turn the main output on. */
:OUTPut ON
/*Turn the SYNC output on, if required. */
:OUTPut:SYNC ON
If the above commands are executed correctly, a square waveform will be seen
on your oscilloscope.
Selecting the Active
Channel
Use the following command to select the active channel:
INSTrument:SELect {A | B}
When “A” is selected, commands will control parameters that are unique for
the channel A output. Selecting “B”, modifies the control of channel B
parameters. The default option is “A”. Parameters that are common to both
Содержание 3162A/B
Страница 4: ...This page was left intentionally blank...
Страница 10: ...3162A B User Manual vi Support Offices 6 2...
Страница 12: ...3162A B User Manual viii This page was left intentionally blank...
Страница 17: ...User Manual 3162A B Getting Started 1 5 Figure 1 2 The Front Panel...
Страница 23: ...User Manual 3162A B Getting Started 1 11 Figure 1 7 WaveCAD Example...
Страница 27: ...User Manual 3162A B Getting Started 1 15 This page was left intentionally blank...
Страница 28: ......
Страница 34: ...3162A B User Manual Configuring The Instrument 2 6 This page was left intentionally blank...
Страница 78: ......
Страница 134: ...User Manual 3162A B Maintenance and Performance Checks 5 32 This page was intentionally left blank...