8.4
Adjusting the restoring force of the
hydraulic stone protection system
Adjustment instructions
Minimum pressure: 120 bar (factory setting)
0D[LPXPSUHVVXUHEDU
ʈ
,IWKHGHÀHFWLRQRIWKHSORXJKERGLHVLVLQVXI¿FLHQWLQFUHDVH
pressure gradually.
ʈ
6HWWKHUHVWRULQJIRUFHVRWKDWWKHSORXJKERGLHVVLW¿UPO\LQ
WKHJURXQGEXWFDQGHÀHFWXSZDUGVVOLJKWO\RYHUVWRQHV
Adjustment
bar
1000
2000
3000
4000
5000
psi
0
100
200
300
400
zu / close / fermée
auf / open / ouverte
ɡɚɤɪɵɬɨ
открыто
3.
1.
2.
4.
Key
1 Supply
hose
2 Valve
open
3 Manometer
4 Valve
closed
ʈ
1. Connect the hydraulic hose for the automatic stone
protection system to a single-acting control device on the
tractor.
ʈ
2. Open the shut-off valve.
ʈ
3. Adjust the hydraulic pressure on the manometer.
ʈ
4. Once the pressure has been reached, close the shut-off
valve.
Adjusting the angle lever stop
1
2
4
3
Key
1 Intermediate
leg
2 Console
bearings
3 Angle
lever
4 Stop
ʈ
To ensure that the intermediate leg (1) is touching the console
bearings (2) without play, there must be a gap between the
angle lever (3) and the stop (4).
ʈ
The distance between the angle lever (3) and the stop (4)
PXVWEHDSSUR[LPDWHO\PP
5
6
Adjustment
ʈ
Reduce hydraulic pressure.
ʈ
Unscrew the locking nut (5, WAF 36 mm).
ʈ
Adjust the distance by turning the adjusting bolt
(6, WAF 36 mm).
Screwing the bolt in = increase the distance
Screwing the bolt out = decrease the distance
ʈ
Tighten the locking nut.