KORMORAN PL V 180 / PL VHA 180
OPERATING
INSTRUCTIONS
- 29 -
9901.00.23EN00 - 01/2016
7.4
Function selection switch (optional)
7.4.1
Installing the function selection switch
1
2
3
on off
1
2
5
4
3
Key
1
Suction device with mechanical lock
2
Cab power supply cable
3
Electric valve connector
4 Extension
5 Black
cable
IMPORTANT:
Check the cable lengths: They must not be too short
(risk of breaking or tearing off) and they must not
be too long (cable gets clamped or crushed in the
mechanical joints, the wheels, etc.).
ʈ
$I¿[WKHKRXVLQJSURWHFWLWDJDLQVWGXVWDQGPRLVWXUHLQWKH
cab by rotating the thumb wheel (item 1) on the suction cup.
ʈ
The two connection cables for the housing (items 2 and 5)
must be connected properly.
ʈ
The tractors are equipped with a connector (3-pin DIN
plug, European standard) (in the cab). Power supply for the
selection switch (item 2).
ʈ
If there is a continuous supply, set the switch to the stop
position (lower switch position). You can prevent the tractor's
battery discharging in this way.
ʈ
The grey cable (item 5) is used to connect the switch to the
H[WHQVLRQLWHPDQGWKHVROHQRLGYDOYHVLWHPWKDWDUH
installed on the implement's coupling head.
IMPORTANT:
If the implement is parked outside, store the housing
in a clean, dry place.
IMPORTANT:
If the controller malfunctions, check the power
supply to the solenoid valves. Remove the sheet
metal case that protects the solenoid valves.
The connections (item 3, 4-pin DIN plug) are
equipped with a green LED that illuminates when the
power supply is correct.